- Products
Application:
For differential pressure measurement requiring purge to protect instrument and impulse lines against corrosive fluids and gases.
General:
Compact design with vent valve, integral filter – 750 microns and spring loaded check valves to prevent back-flow. Suitable for direct mounting to instrument impulse lines.
Connections:
- Purge inlet G1/4”
- ¼“ and ½“ NPT connections are available.
- Purge outlet 10mm (3/8”) outside diameter
- Tube compression fitting vent connection G¼“.
Operating Conditions:
- Maximum working pressure: 413 Bar at 38°C
- Maximum working temperature: 200°C
Valve head | Colour | Type |
---|---|---|
Vent | Red | Anti tamper |