Go to content | Review accessibility aids for this Web site |
 

MX10 4-Valve Manifold

Suitable for direct mounting to instrument.

Double isolate, Equalise and Vent valve

Application:
For general liquid and gas measurement applications, using D.P. transmitters.

Operating Conditions:
-
Maximum working pressure: 413 Bar at 38°C
- Maximum working temperature: 200°C

Connections:
-
Process Inlet and Vent port G¼“ parallel thread with locking pin facility.
- ¼“ and ½“ NPT connections are available.
- Instrument facing to DIN 19213 Form B3
- Instrument Seal Ring Material: PTFE

 

MX10 Double Isolate/Equalise/Vent
 

 

All valve heads colour coded and labelled as follows:


Valve head Colour Type
Isolate Blue Tee bar handle
Equalise Green Anti tamper
Vent Red Anti tamper